Self-regulating heating cable for frost protection of pipes and reservoirs without steam cleaning.
Supply electrical voltage : 12, 24, 48Vac
Maximum rating temperature with power on : 50°C
Maximum exposure temperature power off : 65°C
Temperature classification (accordance with European Standard EN 500114) : T6 (85°C)
Minimum installation temperature : -20°C
Minimum bend radius at - 20°C : 5 mm
Maximum bend radius at 20°C : 13 mm
Weight : 7 kg/km
Maximum conductor resistance at 20°C : 144 Ohms/km
Diameter conductor stranded nickelled copper : 0.48 mm
Section conductor : 0.14 mm²
Color : Blue
Area classification
Ordinary area
Nature of piping
Steel
Painted surface
Stainless steel
Plastic
Chemical resistance
Thermoplastic elastomer
Other insulation on demand
UV
Electric protection
Self-regulating cables must be installed with a circuit breaker or a differential magneto interrupter (curve C or K) 30mA caliber in order to assure physical people and self-regulating tape protection. (D NFC 15-100 Norm).
Indispensable accessories for installation :
Endings kit (KT01), connection case (BR03), aluminium adhésive tape (A01), Thermostat (TH01).
Installation accessories :
Case support (SB01), stainless steel collars (CL01).